Insights & guides

Understanding BASIX Requirements for Residential Projects in NSW

BASIX is the NSW sustainability assessment system for residential development. It considers water efficiency, energy use and thermal performance and forms part of the approval documentation for applicable projects.

BASIX applies to new residential developments, alterations and additions valued at $50,000 or more, and swimming pools or spas with a capacity greater than 40,000 litres.

What does BASIX assess?

The assessment covers three main areas:

Current assessments may also require information about proposed building materials and their embodied emissions.

Which residential projects require BASIX?

BASIX generally applies to:

The correct BASIX assessment pathway depends on whether the proposal is a single dwelling, multi-dwelling development or alteration and addition to an existing home.

When is the BASIX certificate prepared?

The design should be sufficiently developed before the final assessment is completed. The assessor generally needs coordinated information about:

Preparing the certificate too early may lead to repeated revisions if the design changes.

Water-efficiency commitments

The water section may consider:

The required commitments depend on the project type, location and design.

Energy commitments

The energy assessment may include:

Equipment selections should be realistic and coordinated with the electrical and mechanical requirements of the project.

Thermal performance

Thermal performance considers how the building responds to heat and cold. Important design inputs include:

These items affect comfort, heating and cooling demand and the ability of the design to achieve the required performance.

NatHERS and thermal simulation

Depending on the project and assessment method, a NatHERS-accredited assessor may prepare thermal-modelling documentation.

The model uses information from the design drawings, including orientation, construction materials, insulation, glazing, shading and room arrangements.

The drawings, NatHERS information and BASIX certificate must be coordinated. Inconsistent window sizes, materials or insulation specifications can create approval and construction problems.

Why window design matters

Windows can have a major effect on thermal performance.

The assessment may be influenced by:

Large areas of glass may provide views and daylight but can increase heat gain or heat loss if they are not designed and specified appropriately.

Insulation and construction systems

The assessment must reflect the intended construction method. Relevant information may include:

Changing the construction system after the certificate is issued may require the assessment and certificate to be updated.

Do the BASIX commitments need to appear on the plans?

Yes. The commitments shown on the BASIX certificate must be accurately reflected in the drawings and project documentation.

This may include notes or schedules for:

What happens if the design changes?

Changes to windows, floor areas, construction materials, insulation, shading, services or other assessed items may require a revised BASIX certificate.

The updated certificate should be coordinated with the latest drawings before approval or construction documentation is finalised.

Common BASIX coordination mistakes

Coordinate BASIX early

Energy and water performance should influence the design rather than being treated only as a final approval document. Early coordination can reduce redesign and help create a more comfortable and efficient home.

Requirements can change, so the current NSW Planning Portal information and project-specific assessment pathway should always be confirmed.

iRoom Design coordinates building design, BASIX and NatHERS information, approval documentation and consultant inputs for residential projects across Sydney and throughout NSW.